LeakXpert
Powered with Polywater
Specialized transformer maintenance

Repair active transformer leaks without draining oil.

A field-ready PowerPatch system engineered to seal oil leaks on electrical transformers while reducing shutdown time and repeat maintenance.

Tested pressure
Up to 200 PSI
Thermal resistance
Up to 150°C
Electrical safety
Dielectric
Oil compatibility
Chemically inert
Maintenance
Easily removable
Operational advantage / 01

A smarter field repair approach

Traditional methods
LeakXpert approach
Complete kit / 02

Everything needed for onsite application

A coordinated repair system for surface preparation, stopping active leakage, and applying the final seal.

01
50 ml reusable two-part PowerPatch cartridge
02
7-inch two-part putty
03
Static mixing nozzles for application
04
Gun Tool 50-11 for cartridge dispensing
05
Surface preparation wipes and abrasive strips
Application demonstration / 03

See the repair system in action

Watch how the kit is prepared and applied at the leak point in a real transformer maintenance setting.

Field proof / 04

Before. During. After.

A documented repair sequence showing the active leak, sealant application, and completed seal.

01 / Before
Active oil leakage
02 / During
PowerPatch applied
03 / After
Leak sealed
Industry relationships

Selected customers

A dedicated showcase for organizations using LeakXpert in transformer maintenance.

Customer 01
Customer 02
Customer 03
Customer 04
Customer 05
Customer 06
Customer 07
Customer 08
Customer 09
Customer 10
Technical overview / 05

Built for transformer maintenance conditions

Property
Performance
Maintenance benefit
Electrical behavior
Dielectric, non-conductive
Suitable for electrical equipment repair
Pressure testing
Up to 200 PSI
Supports demanding leak conditions
Temperature
Cured sealant sustains up to 150°C
Handles transformer heat cycles
Oil interaction
Chemically inert
Does not react with transformer oil
Removal
Cured material is removable
Supports future planned maintenance
Technical library / 06

Product documents

Review the verified test data, field procedure, product guidance and detailed repair reference.

Technical Data Sheet
Performance, compatibility and test data
Application Procedure
15-step field application workflow
Product FAQ
Cure, temperature and material guidance
Product Flyer
Benefits, applications and kit options
Case Study Reference
160 MVA transformer field repair
FAQ / 07

Technical questions, answered

Yes. The system is designed to arrest active leakage without opening the transformer or draining oil.

Cured sealant sustains up to 150°C, suited to transformer heat cycles.

Yes. PowerPatch is dielectric and non-conductive, suitable for electrical equipment repair.

Add compatible surface details from the product data sheet.

Add shelf-life details from the product data sheet.

Technical sales & support

Ready to stop repeat transformer leaks?

Contact the LeakXpert team for product availability, technical questions, and application support.